Icing Detector for Runway, Road, Structures and Aircraft
New instrument for continuous monitoring of surface conditions (dry, wet, or icy) for airports, roads, aircraft, ships, structures, and other surfaces.
Characteristics
 Instant detection and continuous signal on dry, wet, and icy surface conditions
 Insensitivity to common surface contamination
 Probe sizes: from 1 cm^2 to 10 cm^2
 Power supply: any AC or DC; normal: 120 VAC/0.5 Amp
 Probes mounted within 3 meters from the instrument
 Enclosure: size 20 x 25 x 8 cm, NEMA enclosure available, can be installed in the ground
 Optional multiple probes and probe arrays connected to one instrument
Applications
 Runways and Taxiways, Roads, and Bridges
 Aircraft Surfaces, Jet and Gasoline Engine Inlets
 Shipping: River and Sea Ice
 Refrigeration and Industrial Processes
 Geosciences: River and Sea Ice, Permafrost, Glaciation,...
 Research and Development
Description
Using a combination of selected electrical properties and surface temperature of the monitored surface are simultaneously measured, and surface conditions (dry, wet, or icy) are determined by a logic circuit. The monitoring probe is a two electrode probe which is customized for the desired application (see Figures 1 and 2).
The probe is a part of the monitored surface. It is glued or bolted to the surface and connected with a short cable to the electronic monitor (see Figure 3).
The normal signal output is a standard voltage (0 to 5 V) or current (4 to 20 mA) output which can be connected to a recorder (see Figure 4) and a three relay output for alarms and signal lights. Digital output is provided on request.
Figure 1. Probe for Runways and Roads
Figure 2. Probes for Aircraft and Structures
Figure 3. Instrument Configuration
Figure 4. Instrument Signal
Please specify the following when ordering
 Application: Runway, Road, Bridge, Aircraft, Other (describe)
 Number of Probes per Instrument
 Monitor Box Placement
 Distance between Probe(s) and Monitor
 Type of Output: Analog 1-5V, 4-20 mA, digital-cable, digital-wireless
 Monitor Enclosure: NEMA, other (specify)
 Expected Contaminants (list all that apply): soil, oil, salt, acids, glycol, other (specify)
|